MAN B&W 12 V 40 / 45 GENERATOR PLANT
Generator Plant
In Nearly New Condition
Engine
Manufacturer: MAN B&W
Type: 12 V 40 / 45
Commissioning Date: 2001
Electrical Output: 7260 kWmech
6970 kWel
Operating Hours 21.000 h
Fuel: HFO / Diesel
Optional vegetable Oil
Fuel Consumption: 189 g/kWh
at HFO100% load
Cylinders: 12 in V
Speed: 600 rpm
Alternator
Manufacturer: Leroy Somer
Type: LSA 60.95/10P
Rating: 8712 kVA
Voltage: 600V
Cos φ: 0.8
Frequency: 50 Hz
Speed: 600 rpm
Steam Boiler
Thermal Production
Heat Recovery Power:
Thermal Output: 4557 kWth
Steam: 3.5 t/h
8 bar
175°C
Hot Water: 34 m³/h
65 °C
HFO Burner Power:
Thermal Output: 4433 kWth
Steam: 6.5 t/h
8 bar
175°C.
Ref. 81270
MAN B&W 7 MWEL / 4.5 MW DIESEL POWER PLANT
Used Diesel Power Plant
One (1) used 7 MWel / 4.5 MWth“MAN B&W” Diesel
Generator Plant
In Nearly New Condition
Engine
Manufacturer: MAN B&W
Type: 12 V 40 / 45
Commissioning Date: 2001
Electrical Output: 7260 kWmech
6970 kWel
Operating Hours 21.000 h
Fuel: HFO / Diesel
Optional vegetable Oil
Fuel Consumption: 189 g/kWh
at HFO100% load
Cylinders: 12 in V
Speed: 600 rpm
Alternator
Manufacturer: Leroy Somer
Type: LSA 60.95/10P
Rating: 8712 kVA
Voltage: 600V
Cos φ: 0.8
Frequency: 50 Hz
Speed: 600 rpm
Steam Boiler
Thermal Production
Heat Recovery Power:
Thermal Output: 4557 kWth
Steam: 3.5 t/h
8 bar
175°C
Hot Water: 34 m³/h
65 °C
HFO Burner Power:
Thermal Output: 4433 kWth
Steam: 6.5 t/h
8 bar
175°C
All Diesel Generator set relevant auxiliaries are including
Ref. 91245
MITSUI SHIPBUILDING & AMERICA SOLAR TURBINE MADE, GAS TURBINE GENERATING SYSTEM JV
Commodity :GAS Turbine Generating System JV
Max :4970kw+1890kw CO-Generation Type (GAS Turbine+Steam Turbine)
Generator :6,000kw
Year :2002-2004 (Under checking)
Ref. 91287
GAS POWERED CHP PLANT
GAS POWERED CHP PLANT
Iggesund Paperboard (Workington) Ltd has for sale its Gas-Powered Combined Heat and Power (CHP) Plant.
The plant, currently, is in continuous operation supplying the adjacent paper mill with power and steam. The plant will be permanently closed during April 2013 and available for relocation by the Buyer at that time.
All items will be sold as seen without explicit or implied warranty. The Buyer will remove the plant from site.
DESCRIPTION
The Iggesund paper mill has used the gas fired CHP plant to provide the mill with electricity and steam. The CHP plant was built in 1995/96 to replace the boilers serving the paper mill at that time. The plant was commissioned in 1997.
The CHP plant is based around a GE LM6000PA aero-derivative gas turbine. The gas
turbine can supply up to 42 MWe with an additional 7 MWe being supplied from a Siemens back pressure steam turbine. In addition the plant can continuously supply up to 105 tonnes per hour (tne steam/hour) of steam with short term peak capacity of 120 tne steam/hour.
The gas turbine exhausts into a Nooter Erikson heat recovery steam generator (HRSG) but also has the option to exhaust directly to the atmosphere through a blast stack. This enables the gas turbine to be run in open cycle mode if the HRSG is not available. The HRSG has supplementary gas burners which can be run in addition to the gas turbine or can be run without the gas turbine by using forced draft (FD) fans to supply combustion air. This adds considerable flexibility to the plant.
EQUIPMENT LIST
• 1 x General Electric (GE) model LM6000PA Gas Turbine (GT) with water injectioncoupled to a Brush alternator rated at 42 MW output. The GT is capable of being fired by natural gas or distillate fuel.
• 1 x GT MK V control unit and associated auxiliary systems.
• 1 x Nooter Erikson Heat Recovery Steam Generator (HRSG) which is heated by the exhaust gas from the GT and capable of supplementary firing with natural gas or distillate fuel. Maximum steam output 105 tne steam/hour.
• 1 x Water treatment plant consisting of two 100% twin bed resin exchange units and two mixed bed units (for GT water injection) complete with all auxiliary systems including chemical storage and effluent tanks.
• 1 x Siemens back pressure steam turbine driven generator set rated at 7 MW output.
• 2 x Bellis and Morcom 3 stage reciprocating natural gas compressors, operated as one running unit and a spare.
• 1 x distillate oil tank, capacity 1,500,000 litres.
• 1 x Heavy Fuel Oil storage tank and associated fuel pumps and pipe work.
• 2 x 11/132 kV transformers, each rated at 40 MVA.
• 1 x standby diesel generator.
• 1 x Serck Distributed Control System (DCS).
• 3 x Control and general service air compressors.
• 1 x Boiler chemical dosing system.
• 1 x CBISS Continuous Emissions Monitoring System (CEMS) for monitoring and recording stack gas emissions.
• 1 x Cooling tower complete with dump condenser cooling water pumps dosing sustems and auxiliaries.
• 1 x CHP control building and facilities within.
• 1 x Additional office building.
• 1 x installed fire detection and suppression system.
• 1 x installed security cameras and associated equipment.
• 1 x installed gas detection system.
• All MP and LP steam pressure reducing stations and associated equipment.
• All installed cabling, transformers and switchgear associated with the above mentioned plant.
• Spare parts unique to the machinery scope as available.
• Extensive manuals, records and drawings as available.
PERFORMANCE
The CHP plant had a steam delivery availability of around 97% for 2011. There have not been any major outages, planned or unplanned, in 2012 to date. A summary of power and steam production over the past year is available.
Ref. 11353